UK Underfloor Heating Area, Output & Cost Calculator
Enter the floor area available for heating. Compare electric mats, wet underfloor heating and radiators for the same room and annual heat demand.
Your room and floor layout
Exclude fixed cabinets, furniture and unusable strips. Use the room’s design heat loss and a separate estimate for annual useful space heat. Estimate room heat loss
Electric mat
Coverage sizes the target mat area. Check kit sizes and the layout against the available floor. Use a supplier’s estimate of useful output into the room for the floor and covering.
Wet underfloor
Confirm spacing, flow and return temperatures, floor build-up, finish limits and output with the system supplier. The loop estimate evenly divides the floor pipe and adds two leads per loop. Confirm actual routing and pressure loss before ordering. Uponor underfloor design factors
Installed costs and tariffs
Starting install prices and performance figures illustrate one room. Enter comparable fitted quotes and your own efficiencies and rates. Default rates use the Ofgem Great Britain average, Direct Debit, 1 October to 31 December 2026.
Floor area and heating output
15 m² clear floor
- Target mat area
- 13.5 m²
- Mat electrical load
- 2,025 W
- Estimated useful mat output
- 1,012.5 W (12.5 W surplus)
- Wet pipe including manifold leads
- 112 m
- Wet pipe circuits
- 2 at about 56 m each
- Estimated useful wet floor output
- 1,050 W (50 W surplus)
Installed and annual running costs
Each option supplies 1,200 kWh/year of useful heat. The wet floor and radiator use the selected gas boiler.
- Electric mat
- £750 installed · £316/year
- Wet underfloor
- £1,400 installed · £106/year
- Radiator
- £450 installed · £106/year
Bills assume each system can supply the full annual heat demand. Electric mats use direct resistance at an assumed 1 kWh of electricity per kWh of useful heat for this cost comparison. Standing charges, generator replacements and maintenance are outside the comparison.
Size a radiator for this roomFrequently asked questions
Which floor area should I enter?
Measure the room and subtract areas the proposed layout cannot heat, such as fixed cabinetry. Check the planned coverage and permitted floor finish with the system supplier.
Why compare all three options at the same heat demand?
The room needs a given amount of useful heat over the year. Keeping this demand consistent shows how tariffs and the chosen heat source change the bill.
Can I order a wet system from the pipe length estimate?
Use it to review a proposed layout. Final loop lengths, spacing, flow rates and manifold placement need to be checked against the design and supplier specifications.